Oval Gear Flow Meter
- Commodity name: Oval Gear Flow Meter
- Product Description
-
Overview
The oval gear flow meter is a volumetric measuring instrument used for continuous or intermittent measurement and control of liquid flow in pipelines. It has many advantages such as a wide range, high accuracy, low pressure loss, strong viscosity adaptability, the ability to measure high-temperature and high-viscosity liquids, convenient calibration, and installation recommendations. It is suitable for flow measurement in sectors such as petroleum, chemical industry, chemical fiber, transportation, commerce, food, and medical health.
Working Principle
The flow meter consists of a measuring box and a pair of oval gears installed inside the measuring box, forming a sealed initial crescent-shaped cavity as the unit for calculating the primary displacement. When the liquid to be measured enters the flow meter through the pipeline, the pressure difference generated at the inlet and outlet drives a pair of gears to rotate continuously, constantly transporting the liquid measured through the initial crescent-shaped cavity to the outlet. The number of revolutions of the oval gears multiplied by four times the primary displacement equals the total amount of liquid flow being measured.
Technical Parameters
Model
ItemLC-A Cast Iron LC-E Cast Steel LC-B Stainless Steel Nominal Pressure MPa 1.0 1.6 2.5 4.0 6.4 1.0 1.6 Measured Liquid
Viscosity2-200mPa.s Measured Liquid
Temperature-20℃ to +100℃ Flow Range m3/h Model LC-A Cast Iron LC-E Cast Steel LC-B Stainless Steel Accuracy
Grade
Nominal Port
Diameter DNmm0.5 Grade 0.2 Grade 0.5 Grade 0.2 Grade 0.5 Grade 0.2 Grade 10 0.08 to 0.4 0.1 to 0.4 0.08 to 0.4 0.1 to 0.4 0.1 to 0.5 0.1 to 0.5 15 0.25 to 1.5 0.3 to 1.5 0.25 to 1.5 0.3 to 1.5 0.3 to 1.5 0.3 to 1.5 20 0.5 to 3 0.6 to 3 0.5 to 3 0.6 to 3 0.6 to 3 0.6 to 3 25 1 to 6 1.2 to 6 1 to 6 1.2 to 6 1.2 to 6 1.2 to 6 40 2.5 to 15 3 to 15 2.5 to 15 3 to 15 3 to 15 3 to 15 50 4 to 24 4.8 to 24 4 to 24 4.8 to 24 4.8 to 24 4.8 to 24 80 10 to 60 12 to 60 10 to 60 12 to 60 12 to 60 12 to 60 100 16 to 100 20 to 100 16 to 100 20 to 100 20 to 100 20 to 100 150 32 to 190 38 to 190 32 to 190 38 to 190 38 to 190 38 to 190 200 34 to 340 68 to 340 34 to 340 68 to 340 68 to 340 68 to 340 Installation Precautions for Flow Meters
1. The pipeline should be thoroughly cleaned before installation, and a filter should be installed before the flow meter to prevent debris from entering it. If the measured liquid contains gas, an air separator should be installed.
2. It is important that the axis of the oval gear of the flow meter is installed horizontally, meaning that the dial should be vertical to the ground. Valves for adjusting flow and starting or stopping should be installed at both ends of the flow meter.
3. The arrow on the flow meter housing should point in the same direction as the liquid flow in the installed pipeline.
4. For continuous flow pipelines, a bypass valve should be installed on the horizontal pipeline where the flow meter is installed for regular cleaning and maintenance. In vertical pipelines, the flow meter should be installed in a bypass pipeline to prevent debris from falling into the instrument.
Key words:
Product inquiry
If you are interested in our products, please leave your email, we will contact you as soon as possible, thank you!
Related Products
OEM
From precise design drawings, to rigorous production processes, to strict quality testing, we always uphold the spirit of ingenuity, the pursuit of every detail of the perfect. Our team has a wealth of industry experience and technical strength, according to your specific needs, to provide personalized customized services, to ensure that each product can meet your expectations.